| Type | Nominal Pressure (MPa) |
Test Pressure (MPa) | Applicable Temperature (°C) |
Applicable Media | |
|---|---|---|---|---|---|
| Strength (water) | Seal (water) | ||||
| Z545T -10 | 1 | 1.5 | 1.1 | ≤100°C | Water |
| Z545W -10 | 1 | 1.5 | 1.1 | ≤100°C | Oils |
| Z545T -6 | 0.6 | 0.9 | 0.66 | ≤100°C | Water |
| Z545W -6 | 0.6 | 0.9 | 0.66 | ≤100°C | Oils |
| Model | Nominal Diameter | Size | |||||
|---|---|---|---|---|---|---|---|
| mm | L | D | D1 | D2 | b-f | Z-0d | |
| Z445T/W-10 | 900 | 780 | 1110 | 1050 | 1005 | 46-5 | 28-φ34 |
| 1000 | 840 | 1220 | 1160 | 1115 | 50-5 | 28-φ34 | |
| Z545T/W-10 | 900 | 780 | 1110 | 1050 | 1005 | 46-5 | 28-φ34 |
| 1000 | 840 | 1220 | 1160 | 1115 | 50-5 | 28-φ34 | |
| 1200 | 960 | 1450 | 1380 | 1325 | 56-5 | 32-φ41 | |
| 1400 | 1080 | 1675 | 1590 | 1530 | 62-5 | 36-φ43 | |
| 1600 | 1000 | 1915 | 1820 | 1750 | 68-5 | 40-φ49 | |
| 1800 | 1500 | 2115 | 2020 | 1950 | 72-5 | -- | |
| Z545TW-6 | 1200 | 960 | 1405 | 1340 | 1295 | 40-5 | 32-φ34 |
| 1400 | 1080 | 1630 | 1560 | 1510 | 44-5 | 36-φ37 | |
| 1600 | 1000 | 1820 | 1760 | 1710 | 48-5 | 40-φ34 | |
| 1800 | 1500 | 2045 | 1970 | 1918 | 50-5 | -- | |
The Z545T models are configured specifically for water applications, whereas the Z545W models are optimized for handling oils and hydrocarbon liquids, both operating safely up to 100°C.
For 1.0 MPa (10 bar) nominal pressure units, shell strength testing using water is conducted at 1.5 MPa, while seat sealing tests are verified at 1.1 MPa.
Valves rated for 0.6 MPa (6 bar) nominal pressure undergo shell strength testing with water at 0.9 MPa and seat sealing tests at 0.66 MPa.
The Z545T/W-10 model covers wide large-diameter requirements ranging from 900 mm to 1800 mm nominal diameters (DN 900 - DN 1800).
All specified models including Z545T, Z545W, and Z445T/W are rated for operating environments with temperatures less than or equal to 100°C (≤100°C).
Flange parameters like outer diameter (D), pitch circle diameter (D1), and bolt hole configurations (Z-0d) scale proportionally with nominal size, accommodating heavy-duty industrial pipe connections up to DN 1800.